                Main Products:Electromagnetic Flow meter  Metal Tube Flow Meter  Glass Tube flow Meter
                 
                 
                 
                 
                 
                Glass Tube Flowmeter
                LZB/LZJ series glass rot...
                Glass Tube Flowmeter
                Glass Tube Flowmeter
                LZB-()W/WB series micro ...
                Glass Tube Flowmeter

                 


                Turbine Flow meter
                Product Model:LWQ

                1.Summary:


                LWGY series turbine flow meters have the features: high accuracy, good repeatability, convenient installation/maintenance, simple structure etc.…
                ……………………………….


                Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil. This signal is converted into engineering units (liters, cubic meters, gallons etc.) on the local display where is applicable. Optional accessory modules can be used to export the signal to other equipment.

                Upon receipt, examine your meter for visible damage. The turbine is a precision measuring instrument and should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items are damaged or missing, contact CHENGFENG FLOWMETER.………………………

                Make sure the turbine flow model meets your specific needs. For your future reference, it might be useful to record this information on nameplate in the manual in case it becomes unreadable on the turbine. Refer to the nameplate for your customized product’s specification.
                2. SPECIFICATION
                Performance
                Repeatability:         ±0.2%
                Accuracy:            Standard:±1% of reading;
                Optional:±0.5% of reading
                Wetted Components
                Housing:             Standard:304SS;
                Optional:316SS
                Bearings and Shaft:    Tungsten Carbide
                Rotor:               Standard-2Cr13 Stainless Steel
                (Optional Alloy CD4Mcu)
                Retaining Rings:       316 Stainless Steel
                Output Signal:(Where applicable)
                Sensor:             Pulse signal(Low level:≤0.8V,High level≥8V)
                Transmitter:         4 to 20 mA DC current signal
                Signal Transmission Distance:1000m
                Electric Connections:
                Basic Type:             Hausman connector or Three core cable
                Explosion Proof Type:    ISO M20×1.5 Female
                Explosion Proof Level:
                Standard:             None ;  
                Optional:             ExdIIBT6
                Protection Level:         IP65
                3. OPERATION CONDITIONS
                Ambient:
                Temperature:         -10℃ to +55℃
                Pressure:            86 to 106KPa
                Relative Humidity:    5% to 90%
                Power Supply:
                Sensor:                +12V DC(Optional:+24V DC)
                Transmitter:            +24V DC
                Field Display Type B:    Integral 3.2V Lithium Battery(Others available on request)
                Field Display Type C:    +24V DC
                Fluid Temperature and Pressure:
                Temperature:         -20℃ to +110℃
                Pressure:            Fluid pressure should be limited according to rating.
                Measurable Flow Rate Range and Pressure Level:(See table 1)
                Table 1.Measurable Flow Range and Pressure Rating


                Nominal Diameter

                Standard Flow Range
                (SFR)

                Extended Flow Range
                (EFR)

                Standard Pressure Rating

                Customized Pressure Rating

                (mm)

                (in.)

                (m3/h)

                (m3/h)

                (MPa)

                (MPa)-Flange fitting

                4

                0.15

                0.04~0.25

                0.04~0.4

                Thread:6.3

                12,16,25

                6

                0.25

                0.1~0.6

                0.06~0.6

                Thread:6.3

                12,16,25

                10

                0.4

                0.2~1.2

                0.15~1.5

                Thread:6.3

                12,16,25

                15

                0.5

                0.6~6

                0.4~8

                Thread:6.3;Flange:2.5

                4.0,6.3,12,16,25

                20

                0.75

                0.8~8

                0.45~9

                Thread:6.3;Flange:2.5

                4.0,6.3,12,16,25

                25

                1

                1~10

                0.5~10

                Thread:6.3;Flange:2.5

                4.0,6.3,12,16,25

                32

                1.25

                1.5~15

                0.8~15

                Thread:6.3;Flange:2.5

                4.0,6.3,12,16,25

                40

                1.5

                2~20

                1~30

                Thread:6.3;Flange:2.5

                4.0,6.3,12,16,25

                50

                2

                4~40

                2~40

                Flange:2.5

                4.0,6.3,12,16,25

                65

                2.5

                7~70

                4~70

                Flange:2.5

                4.0,6.3,12,16,25

                80

                3

                10~100

                5~100

                Flange:2.5

                4.0,6.3,12,16,25

                100

                4

                20~200

                10~200

                Flange:1.6

                4.0,6.3,12,16,25

                125

                5

                25~250

                13~250

                Flange:1.6

                2.5,4.0,6.3,12,16

                150

                6

                30~300

                15~300

                Flange:1.6

                2.5,4.0,6.3,12,16

                200

                8

                80~800

                40~800

                Flange:1.6

                2.5,4.0,6.3,12,16

                Model Selection(See Table 2)
                Table 2.Model Selection Guidance


                Model Suffix Code

                Description
                (SFR:Standard Flow Range)

                LWGY-

                /□

                /□

                /□

                /□

                /□

                /□

                Nominal Diameter(mm)

                4

                 

                 

                 

                 

                 

                 

                4mm;SFR:0.04~0.25m3/h

                6

                6mm;SFR:0.1~0.6m3/h

                10

                10mm;SFR:0.2~1.2m3/h

                15

                15mm;SFR:0.6~6m3/h

                20

                20mm;SFR:0.8~8m3/h

                25

                25mm;SFR:1~10m3/h

                32

                32mm;SFR:1.5~15m3/h

                40

                40mm;SFR:2~20m3/h

                50

                50mm;SFR:4~40m3/h

                65

                65mm;SFR:7~70m3/h

                80

                80mm;SFR:10~100m3/h

                100

                100mm;SFR:20~200m3/h

                125

                125mm;SFR:25~250m3/h

                150

                150mm;SFR:30~300m3/h

                200

                200mm;SFR:80~800m3/h

                Type

                C

                Basic Type:+12V~24V DC power supply;pulse output

                F

                4~20mA current output

                Y

                Battery Power Supply with Field Display

                B

                Field Display and 4~20mA current Output

                B1

                Field Display and RS485

                B2

                Field Display and HART

                Accuracy Class

                10

                ±1.0% of Reading

                05

                ±0.5% of Reading

                Measurable Range

                K

                Standard:Refer to Table 1

                S

                Extended:Refer to Table 1

                Hosing Material

                P

                304 Stainless Steel

                R

                316(L) Stainless Steel

                Explosion Class

                 

                Blank:Without Explosion-proof

                E

                Explosion-proof:ExdIIBT6

                Pressure Class

                S

                Standard:Refer to Table 1

                H(x)

                Customized:Refer to Table 1



                ? 2012 Changzhou Chengfeng Flowmeter Co.,Ltd All Rights Reserved   Main Products:Electromagnetic Flow meter  Metal Tube Flow Meter  Glass Tube flow Meter
                Design by Lingdong Internet  Switchboard:86-519-85503558,86-519-85503688  Fax:86-519-85505269,86-519-85503588-8008
                Friendly Links:成豐儀表阿里巴巴店鋪    新浪